Quick Details

  • Place of Origin: Shanghai, China (Mainland)
  • Brand Name: caledonian
  • Model Number: RE-2X(St)H
  • Shielding: Foil
  • Conductor Material: Copper
  • Jacket: PVC
  • Insulation Material: XLPE
  • sheath: lszh

Packaging & Delivery

Delivery Time 30

Specifications

Basic design to BS 5308/BS 7629-1
RE-2X(St)H...CI. FE 180 PH30 ( CU/MGT+XLPE/OSCR/LSZH 300/500V Class 2 )

APPLICATION
The cables are designed, manufactured and tested as data transmission cables for emergency services. These are used for data and voice transmission when high frequency signal has to be assured also in the event of a fire.
STANDARDS
Basic design to BS 5308/BS 7629-1
FIRE PERFORMANCE
Circuit Integrity IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180);
BS 8434-1 (30mins); BS 5839-1 Clause 26 2d; CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)
Circuit Integrity with mechanical shock EN 50200(PH30); CEI 20-36/4-0
Circuit Integrity with mechanical shock & water spray EN 50200 annex E
System circuit integrity DIN 4102-12, E30 depending on lay system
Flame Retardance (Single Vertical Wire Test) EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2;
VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2);
CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
Reduced Fire Propagation   (Vertically-mounted bundled wires & cable test) EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4
Halogen Free IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1;
CEI 20-37/2-1 ; BS 6425-1*
No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2;
CEI 20-37/2-2 ; BS 6425-2*
Minimum Smoke Emission IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2;
CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*
No Toxic gases NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.
CABLE CONSTRUCTION
Conductor: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Mica glass tape covered by extruded cross-linked XLPE compound or fire resistant silicone rubber compound type EI2 as per BS 7655-1.1.
Cabling: The cores are cabled together in concentric layers with suitable non-hygroscopic fillers.
Overall Screen: Aluminum/polyester tape with 0.5mm2 screen (7/0.3mm) with tinned copper drain wire.
Inner Sheath(optional):Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 Armouring(optional): Galvanized steel wire armour
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1(Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.)
VOLTAGE RATING 
300/500 V
COLOUR CODE
Insulation Colour: White with black numberings.
Sheath Colour: Orange (other colours on request).
TYPE CODE
RE-  Instrumentation cable                     H       Halogen free & zero halogen                             
2X        XLPE                                                         2G     Silicon Rubber             
(St)  Static shield of aluminium tape                 SWA  Steel Wire Armoured
FE180  Insulation integrity (950°C 180 minutes)   CI      Circuit integrity
PH 90   Fire Test for 90 mins at 830°C        

Physical AND THERMAL PROPERTIES
Temperature range during operation (fixed state): -30°C – +90°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 6 x Overall Diameter (unarmoured cables with silicone rubber insulation)
                                            8 x Overall Diameter (unarmoured cables with XLPE insulation)
                                           10 x Overall Diameter (armoured cables)

 

Electrical PROPERTIES
Dielectric test: 2000 V r.m.s. x 5’ (core/core)
Insulation Resistance XLPE: ≥1000 MΩ x km (at 20°C)
SR: ≥300 MΩ x km (at 20°C)

Short circuit Temperature   XLPE: 250°C
SR: 350°C

CONSTRUCTION PARAMETERSConductor  RE-2X(St)H.CI. FE 180 PH30
RE-2G(St)H.CI. FE 180 PH30 RE-2X(St)HSWAH...CI. FE 180 PH30
RE-2G(St)HSWAH...CI. FE 180 PH30
No. of Core X Cross Section No./Nominal Diameter of Strands  Nominal   Insulation
Thickness Unarmoured Armoured
   Nominal   Overall
Diameter Approx. Weight Diameter Under Armour Armour Wire Diameter Nominal   Overall Diameter Approx. Weight
mm2 no./mm mm mm kg/km mm mm mm kg/km
2 Core
2x1.0 7/0.43 0.6 8.0 82 8.0 0.90 12.4 288
2x1.5 7/0.53 0.7 8.5 101 8.5 0.90 13.1 342
2x2.5 7/0.67 0.8 10.5 137 10.5 0.90 15.1 419
2x4 7/0.85 0.8 12.5 180 12.5 0.90 17.1 484
3 Core
3x1.0 7/0.43 0.6 8.0 100 8.0 0.90 12.4 324
3x1.5 7/0.53 0.7 9.5 127 9.5 0.90 14.1 383
3x2.5 7/0.67 0.8 12.0 176 12.0 0.90 16.6 466
3x4 7/0.85 0.8 13.5 236 13.5 0.90 18.1 560
4 Core
4x1.0 7/0.43 0.6 9.0 127 9.0 0.90 13.6 383
4x1.5 7/0.53 0.7 10.5 161 10.5 0.90 15.1 445
4x2.5 7/0.67 0.8 13.0 224 13.0 0.90 17.6 548
4x4 7/0.85 0.8 15.0 302 15.0 1.25 20.5 772
7 Core
7x1.0 7/0.43 0.6 11.0 187 11.0 0.9 15.6 485
7x1.5 7/0.53 0.7 12.5 250 12.5 0.90 17.3 597
7x2.5 7/0.67 0.8 15.0 354 15.0 1.25 20.5 862
12 Core
12x1.5 7/0.53 0.7 16.0 402 16.0 1.25 21.7 997
12x2.5 7/0.67 0.8 20.0 585 20.0 1.60 26.4 1421
19 Core
19x1.5 7/0.53 0.7 19.0 597 19.0 1.60 25.6 1465
19x2.5 7/0.67 0.8 24.0 873 24.0 1.60 30.6 1837
Note : Other conductor sizes & core configurations are available upon request.

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
United Kingdom
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $
Learn More